Severn LS40/60 Specifiche

Navigare online o scaricare Specifiche per Asciugatrici elettriche Severn LS40/60. Severn LS40/60 Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 42
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Title
LSG60 Freeze Drier
Customer
SS Reference
Fxxx
Customer Reference
N/A
INSTALLATION AND OPERATION MANUAL
1HZ246
Issue 1
Date 26/10/05
Severn Science Ltd
8 Brunel Way
Thornbury
Bristol
BS35 3UR
Tel 01454 414723
Fax 01454 281680
Please Read This Document before Operating the Machinery
Vedere la pagina 0
1 2 3 4 5 6 ... 41 42

Sommario

Pagina 1

Title LSG60 Freeze Drier Customer SS Reference Fxxx Customer Reference N/A INSTALLATION AND OPERATION MANU

Pagina 2

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” PT100 DisconnectsUnic 10 valve actuator22 mm Straight union (Silicon oil circuit)

Pagina 3

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Heat Exchanger water cooling hoses Silicon oil drain valve Figure 2 2.4.5 Ad

Pagina 4

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 3. OVERVIEW 3.1 General Description The LSG60 Freeze Dryer is for the purpose of dry

Pagina 5

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Oil collected in the mist filter is continuously returned into the gas ballast port

Pagina 6

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” user interface. Navigation between the User screens is achieved using standard displ

Pagina 7

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” MENU KEY Figure 3Section 3 Issue: 1 Page 15 of 42

Pagina 8

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Silicon oil reserviorDrying chamber door Upper viewport Condenser ChamberLower vie

Pagina 9

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 4. FUNCTIONS 4.1 Power up Power up is achieved via the control power switch locate

Pagina 10

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 2. Operator- User is able to download recipes run cycles, view alarm history, histo

Pagina 11

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” CAUTIOshelves pr N: The provided ‘stoppering jacks’ must be placed on all ior to

Pagina 12

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” CONTENTS 1. DOCUMENTATION RECORDS 4 2. INTRODUCTION 5 2.1 Purpose 5 2.2 General

Pagina 13

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Min -40 oC The user is able to load/download a recipe by the following operation

Pagina 14

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” • Press the file name field . A list of program names will appear in the left half

Pagina 15

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” • To run the program, press the RUN key. The Programmer screen will appear. The pro

Pagina 16

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” c) From the Home screen, press the ‘Vent Valve’ icon. The icon changes from Red to

Pagina 17

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Min 0.01 mbar/s EPD retest [hrs] End Point Determination duration between tests Max

Pagina 18

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” describes the freeze drying conditions of either temperature or pressure (pressure i

Pagina 19

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Table 3: Function Descriptions and Coding Function Name Function Description SP cod

Pagina 20

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” To save the updated program under the same file name after editing is complete, or t

Pagina 21

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Select/unselect the automatic backfill option by pressing the appropriate field whi

Pagina 22

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” CAUTIONall shelveresult : The provided ‘stoppering jacks’ must be placed on s pri

Pagina 23

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 4.8 Trends 27 4.9 Setup 27 4.9.1 End Point Determination 27 4.9.2 Secondary Dr

Pagina 24

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Stoppering Hydraulic flow control‘Stoppering’ pressure switch ‘Home’ pressure switc

Pagina 25

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 14. Shelf temperature Auto/Man control 15. Shelf temperature control output 4.11 In

Pagina 26

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 4.13 Historical Logging Data can be logged to the 16MB internal memory during the fr

Pagina 27

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” ‘Export’ causes the currently displayed file to be copied to the floppy disk or USB

Pagina 28

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 5.1.2 Setup Figure 8Section 3 Issue: 1 Page 34 of 42

Pagina 29 - LOCKING NUT

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 5.1.3 Trend Example of a single trend page Figure 9Section 3 Issue: 1 Page 35 o

Pagina 30

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 5.2 Display Navigation Navigation between displays is as follows: HOME SETUP TREND

Pagina 31

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 6. MAINTENANCE WARNINdoor.maint G: There is no safety interlock fitted to the elec

Pagina 32

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 6.2 Recommended Spares 6.2.1 General Table 4: Recommended Spare Parts List Descri

Pagina 33

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 240V 400W, 1/4" COLD AT DISC END, 1/2" COLD AT LEAD END, 39" TEFLON L

Pagina 34

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 1. DOCUMENTATION RECORDS Issue Documentation Update Details Date Approval

Pagina 35

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” Table 5: Technical Specifications FUNCTION MODEL PERFORMANCE Minimum condenser t

Pagina 36

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” • Temperature Operation 0 to + 30°C • Temperature Storage -10 to +70°C • Humidity

Pagina 37

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” PID Proportional / Integral / Derivative 2500 Eurotherm 2500 Input / Output unit

Pagina 38 - WATLOW FIREROD CARTRIDGE

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 2. INTRODUCTION 2.1 Purpose This manual provides installation and operation instruc

Pagina 39 - TEFLON LEAD AND SEAL

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 2.4 Installation and Commission 2.4.1 Initial setup I. Locate the freeze dryer i

Pagina 40

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” CAUTIOclosed pos N: Check that the Gas Ballast control has not been left in the f

Pagina 41

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 2.4.4 Lifting and Handling Instructions 2.4.4.1 General The LSG60 Freeze dryer is

Pagina 42

OPERATION MANUAL “customer” – LSG60 Freeze Drier – “contract ref” 9. Disconnect the four grey flexible braided water cooling hoses. 10. Now remove th

Commenti su questo manuale

Nessun commento